TP 1 · Question sheet
DC motor characterisation and the automatic barrier
Group
Bench no.
Date
Members
Before the session
Answer each preparation question before the session: the answer or working, the value and its unit.
P1 Using manual Table 10-1.1, write the control byte SMB67 for PWM on Q0.0 with a 1 ms time base, and the values of SMW68 and SMW70 for a 200 ms period and a 40 % duty cycle.
ValueUnit
P2 The pointer passes the proximity sensor once per revolution. If Δt (ms) separates two detections, give the speed in rev/min.
ValueUnit
P3 Draw the GRAFCET of the barrier of Part B, with at least the steps closed, opening, open, closing and fault.
ValueUnit
During the session
Answer at the bench, as you go.
D1 From which duty cycle does the motor start to turn? Above which duty cycle does its speed hardly increase?
D2 Write the time Δt between two proximity pulses at 100 % duty cycle, and the speed in rev/min. You will need it in TP 5.
D3 How long does the arm take to open at full speed? Which time did you choose for the change to 30 %, and why?
D4 After ten barrier cycles, what cyclic duration factor do you find?
At the end of the session
Answer when the tests are done, before the group signs the report.
Q1 Plot speed against duty cycle. Where does the curve leave a straight line, and what causes the dead zone at low duty cycle? Relate it to the friction and load torque of Chapter 1.
Q2 Compare the 200 ms and 20 ms PWM periods. Why do industrial drives switch at several kilohertz?
Q3 From your measured on-time and cycle time, what is the cyclic duration factor of the barrier motor? Which IEC 60034-1 duty type describes it, and what would you write on the motor order?
Q4 Why is a movement time-out indispensable when a limit switch is the only proof that a movement has finished?
Checkpoints
| Speed measurement demonstrated at two duty cycles. | Teacher's signature |
| Complete cycle with a vehicle demonstrated. | Teacher's signature |
Marking
| Preparation / 3 | Program / 6 | Bench / 6 | Report / 5 | Total / 20 |